2

Number of cited
Abstract

As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.

  • Kapsamı

    Uluslararası

  • Type

    Hakemli

  • Index info

    WOS.SCI

  • Language

    English

  • Article Type

    None

  • Keywords

    EPS fouling model filtration MBR SMP thermophilic