Abstract
District Heating (DH) systems, owing to their remarkable techno-economic benefits compared to decentral heat production methods, are getting more and more popular worldwide. Today, DH systems are much more efficient than in the past but investigations show that there is still much to explore for more benefits and higher efficiencies considering such systems, where lowering the operating temper-ature is one of the points with the highest potential advantages. This study evaluates the effects of using different levels of operation temperatures of DH systems. For making the assessments quantifiable, specific case study DH network with a CHP plant as the main tool of supply is considered for the analyses. Three different design scenarios for the system are considered for all of which the results of the energy, exergy, and economic analyses are presented for the subsystems and the whole heat grid. Through thermoeconomic analysis, the unit exergy costs of electricity and heat and unit exergy costs of Space Heating (SH) and Domestic Hot Water (DHW) are determined. The results showed that lowering the operating temperatures increased the overall energetic and exergetic efficiencies of the CHP-supplied DH system, while reduced the cost per exergy unit associated with the SH and DHW supply.(c) 2022 Published by Elsevier Ltd.
-
Kapsamı
Uluslararası
-
Type
Hakemli
-
Index info
WOS.SCI
-
Language
English
-
Article Type
None
-
Keywords
District heating Future energy systems Combined heat and power Thermoeconomic analysis Exergy analysis